Electronic Instrumentations |
Designing and production of electronic instrumentation for measurements of weight, force, pressure and torque, used in industrial processes, weighing systems, in research laboratories etc ... |
|
Type |
Div. |
Set Point |
Input |
Power
Supply |
Functions |
Optionals
Notes |
|
|
MP1
Accuracy: 0.05% |
�9.999 |
2 |
2mV/V 1mV/V 3mV/V
4-20mA 0-5V
0-10V |
230Vac 115Vac 24Vdc
12Vdc |
FILTER
ZERO
PEAK |
Analogue output |
|
|
|
|
|
MP2E
Accuracy: 0.005%  |
�50.000 |
4 |
2mV/V 1mV/V 3mV/V
4-20mA 0-5V
0-10V |
230Vac 115Vac 24Vdc 12Vdc |
PEAK
UNLOAD
HOLD |
Load cells fed at carrying frequency RS485 Modbus USB  |
|
|
|
|
|
MP2000
Accuracy: 0.005%  |
�300.000 |
4 |
2mV/V 1mV/V 3mV/V
4-20mA 0-5V
0-10V |
230Vac 115Vac 24Vdc 12Vdc |
PEAK
UNLOAD
HOLD |
Load cells fed at carrying frequency
USB  |
|
|
|
|
|
MP4
Accuracy: 0.01%  |
�50.000 |
2
10 |
2mV/V 1mV/V 3mV/V
4-20mA 0-5V
0-10V |
230Vac 115Vac 24Vdc 12Vdc |
PEAK
UNLOAD
HOLD |
DATA LOGGER
4 input for:
Load cells Dynamometers
Pressure transducers
Dispacements transducers
Torque transducers
Temperature PT100 |
|
|
|
|
|
MP10 Accuracy:0.0025%
10 Programmable Channels

|
�200.000 |
/ |
2mV/V 1mV/V 3mV/V |
230Vac |
LINEARIZATION |
Load cells fed by carrying frequency
RS232 Output |
|
|
|
|
|
MP10/2 Accuracy:0.0025%
2 Programmable Channels

|
�200.000 |
/ |
2mV/V 1mV/V 3mV/V |
230Vac |
SELF CALIBRATION FILTER
ZERO
PEAK
HOLD |
Load cells fed by carrying frequency |
|
|
|
|
|
MP6A
Accuracy: 0.005%

|
�50.000 |
/ |
2mV/V 1mV/V 3mV/V
4-20mA 0-5V
0-10V |
230Vac |
PEAK
HOLD |
Load cells fed at carrying frequency
USB  |
|
|
|
|
|
PC2M
Calibrator
Accuracy:0.0025%

|
/ |
/ |
/ |
/ |
Positive and negative step:
0.0 mV/V
0.4 mV/V
0.8 mV/V
1.2 mV/V
2.0 mV/V |
Signal
calibrator |
|
|
|
|
|
DFI
Accuracy: 0.02%

|
�25.000 |
/ |
2mV/V 1mV/V 3mV/V |
1 year autonomy without recharge |
FILTER
ZERO
PEAK |
Load cells fed at carrying frequency
RS232C |
|
|
|
|
|
DFX
Accuracy: 0.04%
|
�25.000 |
/ |
2mV/V 1mV/V 3mV/V |
1 year autonomy without recharge |
FILTER
ZERO
PEAK |
Load cells fed at continuos tension
RS232C
LOW COST |
|
|
|
|
|
TA4/2
Analog
transmitters
Accuracy: 0.02%

|
/ |
/ |
2mV/V |
24Vdc |
ANALOG
FILTER
ZERO |
DIN bar version (TA4D) |
|
|
|
|
|
TA5F
Digital
transmitters
Accuracy: 0.01%

|
+200.000 |
/ |
2mV/V |
24Vdc |
FILTER
RESOLUTION CALIBRATION
ZERO |
DIN bar version TA5D
RS485
Modbus |
|
|
|
|
|
TAUSB
Digital
transmitters
Accuracy: 0.025%
|
�20.000 |
/ |
2mV/V |
/ |
FILTER
ZERO |
USB  |
|
|
|
|
|
TA2USB
Digital
transmitters
Accuracy: 0.01%

|
�50.000 |
/ |
2mV/V |
/ |
FILTER
ZERO |
USB 
2 input
4 input |
|
|
|
|
|
SG4
Junction box

|
/ |
/ |
/ |
/ |
/ |
DIN bar version SG4D |
|
|
|
|